{"product_id":"mitsubishi-electric-peadzm100v2makit-10kw-ducted-air-conditioner-system-1-phase","title":"MITSUBISHI ELECTRIC PEADZM100V2MAKIT 10kW Low Profile Ducted Air Conditioner 1 Phase","description":"\u003cp\u003eExperience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer's Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock - never a factory second in sight!\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"100\"\u003e\n\u003ccol width=\"100\"\u003e\n\u003ccol width=\"100\"\u003e\n\u003ccol width=\"100\"\u003e\n\u003ccol width=\"157\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003eIndoor Unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePEAD-M100JAAD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003eOutdoor Unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePUZ-ZM 100VKA2-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" rowspan=\"1\"\u003ePower Supply (V, Phase, Hz)\u003c\/td\u003e\n\u003ctd\u003eV: 230 V, Single-phase, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"7\"\u003e\n\u003cdiv\u003eCooling\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eCapacity\u003cbr\u003e[Min-Rated*4-Max]\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e4.90 – 10.00 –\u003cbr\u003e11.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eTotal Input [Rated]*4\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e2.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eEER\/AEER*1\u003c\/td\u003e\n\u003ctd\u003e3.74\/3.60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eRunning Current [Rated]*4\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\n\u003cdiv\u003eSound Pressure Level*2\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIn (Lo-Mid-Hi)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e33 – 38 – 42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOut (PWL)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e49 (69)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eAir Volume (In) Lo-Mid-Hi\u003c\/td\u003e\n\u003ctd\u003eL\/s\u003c\/td\u003e\n\u003ctd\u003e400 – 483 – 567\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"7\"\u003e\n\u003cdiv\u003eHeating\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eCapacity\u003cbr\u003e[Min-Rated*5-Max]\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e4.50 – 11.20 –\u003cbr\u003e14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eTotal Input [Rated]*5\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eCOP\/ACOP*1\u003c\/td\u003e\n\u003ctd\u003e4.00\/3.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eRunning Current [Rated]*5\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e12.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\n\u003cdiv\u003eSound Pressure Level*2\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIn (Lo-Mid-Hi)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e33 – 38 – 42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOut (PWL)\u003c\/td\u003e\n\u003ctd\u003edBA\u003c\/td\u003e\n\u003ctd\u003e51 (69)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eAir Volume (In) Lo-Mid-Hi\u003c\/td\u003e\n\u003ctd\u003eL\/s\u003c\/td\u003e\n\u003ctd\u003e400 – 483 – 567\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eMax. Running Current\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e29.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"4\"\u003e\n\u003cdiv\u003eIndoor Unit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eInput [Rated]\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003ctd\u003e0.25\/0.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eDimensions [HxWxD]\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e250 x 1400 x 732\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eStatic Pressure\u003c\/td\u003e\n\u003ctd\u003ePa\u003c\/td\u003e\n\u003ctd\u003e35\/50\/70\/100\/125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"3\"\u003e\n\u003cdiv\u003eOutdoor Unit\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eDimensions [HxWxD]\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e1338 x 1050 x 330\u003cbr\u003e(+40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eBreaker Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\n\u003cdiv\u003eExt. Piping\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eDiameter [Liquid\/Gas]\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003eø9.52\/ø15.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003eMax. Length\/Height\u003c\/td\u003e\n\u003ctd\u003em\u003c\/td\u003e\n\u003ctd\u003e75\/30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\n\u003cdiv\u003eGuaranteed Operating Range [Outdoor]\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003eCooling*3\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e-15 ~ 52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003ctd\u003e-20 ~ 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eSupply Air Duct\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e1360 x 178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eReturn Air Duct\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003ctd\u003e1358 x 210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003ePre-Charge Refrigerant\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003ctd\u003e4.0kg (30m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"1\"\u003eAdditional Refrigerant\u003c\/td\u003e\n\u003ctd\u003eg\/m\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eShop with Confidence\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBrand new Australian Stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNo Factory Seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull Australian Manufacturer's Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSecure Online Payments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e10.0 kW Cooling | 11.2 kW Heating\u003c\/li\u003e\n\u003cli\u003eMITSUBISHI ELECTRIC \u003cspan data-sheets-root=\"1\"\u003ePEADZM100V2MAKIT\u003c\/span\u003e 10kW Low Profile Ducted Air Conditioner 1 Phase\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cspan data-sheets-root=\"1\"\u003ePEAD-M100JAADR1.TH \/ PUZ-ZM100VKA2-A.TH \/ PAR-41MAAM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eZM Series Power Inverter Outdoor | Low Height Model 250mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":53581130760503,"sku":"PEADZM100V2MAKIT","price":4499.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/0892\/2679\/files\/MITSUBISHI-ELECTRIC-PEAD-M100JAADR1.TH-PUZ-ZM100VKA2-A.TH-10kW-Low-Profile-Ducted-Air-Conditioner-1-Phase-wired-controller.png-400x400.png?v=1794289910","url":"https:\/\/wholesaleaircon.com.au\/products\/mitsubishi-electric-peadzm100v2makit-10kw-ducted-air-conditioner-system-1-phase","provider":"WholeSaleAircons","version":"1.0","type":"link"}