Brivis Ice ADD-ON COOLING DIXU18Z/ DOSC18Z91 18kW Non-Inverter R410A Three Phase


Price:
Sale price$6,211

PLEASE NOTE:
Installation is only available in Sydney, Melbourne, and Brisbane.

Talk to us via our live chat or contact us page for a personalised quote.

Request a Personalised Quote

Direct Door to Door Delivery Available or Pick up option is available at multiple locations. Simply input your address at the checkout page, and the nearest pick-up depot will be displayed as one of your options.

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Description

Experience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer's Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock - never a factory second in sight!

Shop with Confidence

Brand new Australian Stock
No Factory Seconds
Full Australian Manufacturer's Warranty
Secure Online Payments

Specifications

Add on ICE» DualComfort»
System Overview 18
Power Supply V-ph-Hz 415-3-50
Mode Conventional
Nominal Capacity kW 18
Rated Capacity kW 18.2
Capacity Range kW N/A
Rated Input W 5.2
AEER 3.5
ICE» Outdoor Unit DO-SC18Z91
Power Supply V-ph-Hz 415-3-50
Maximum Input Current A 20.9
Compressor Type Scroll
Sound Pressure Level @3m dB(A) 56
Sound Power Level dB(A) 70
Dimensions (L x W x H) mm 1258 _ 450 _ 1390
Net Weight kg 141
Refrigerant Type R410A
Gas Connection Size mm 22.2
Liquid Connection Size 12.7
Recommended Interconnecting Pipe Size Gas (mm) 1 10m 22.2
Recommended Interconnecting Pipe Size Gas (mm) 10 30m 28.6
Recommended Interconnecting Pipe Size Liquid (mm) 1 10m 9.52
Recommended Interconnecting Pipe Size Liquid (mm) 10 30m 12.7
Precharged Length m 15
Max. Pipe Length m 30
Max. Height Diff (CDU below) m 8
Max. Height Diff (CDU above) m 8
Ambient Temperature Limits _C -5 ~ 46
ICE» Indoor Unit DI-XU18Z
Power Supply V-ph-Hz NA
Airflow Rated L/s 900
Airflow Minimum L/s 750
Dimensions (L x W x H) mm 680 _ 627 _ 542
Net Weight kg 36
Duct Connection (Outlet) mm ø 450
Duct Connection (Inlet) mm ø 400
Condensate Drain Connection mm 20
Gas Refrigerant Pipe Connections mm 22.2
Liquid Refrigerant Pipe Connections mm 12.7
Operating Temperature Limits _C 17 ~ 32
Rated capacities rated in accordance with AS3823 with 5m charged length. With our policy of continuous improvement, we reserve the right to change, or discontinue at any time, specifications or designs without notice.

Description

18 kW Cooling

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383