7.1 kW Cooling
8.0 kW Heating

Fujitsu SET-ARTH24KHTA 7.1kW High Static Ducted Air Conditioning System – 1 Phase
Includes 
Indoor Unit ARTH24KHTA | Outdoor Unit AOTH24KBTA
Wired Backlit Controller : UTY-RNRT


Indoor unit ARTH24KHTA
Outdoor unit AOTH24KBTA
Operation Type Reverse Cycle
Power Source
V/Ph/Hz
230 / 1 / 50
Cooling Capacity
kW (Rated (Min – Max))
7.10 (1.8 – 8.1)
Heating Capacity
kW (Rated (Min – Max))
8.00 (2 – 9.1)
Input Power Cooling
kW (Rated (Max))
2.14 (2.53)
Input Power Heating
kW (Rated (Max))
2.05 (2.45)
EER Cooling
kW/kW
3.32
COP Heating
kW/kW
3.9
Star Rating Cooling
(0-10) (Hot / Average / Cold)
3 / 3 / 3
Star Rating Heating
(0-10) (Hot / Average / Cold)
3 / 2.5 / 1.5
Total Cooling Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.912 / 4.611 / 4.875
Heating Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.825 / 4.11 / 3.444
Total Cooling Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
5.299 / 5.489 / 5.931
Heating Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
4.831 / 4.41 / 3.707
Running Current
amps (Cooling / Heating)
9.4 / 9
Moisture Removal
l/hr
0.5
Indoor Sound Pressure Cooling
dBA (High / Quiet)
34 / 27
Indoor Sound Pressure Heating
dBA (High / Quiet)
34 / 27
Outdoor Sound Pressure
dBA (Cooling / Heating)
48 / 50
Outdoor Sound Power
dBA
68
Static Pressure Range
PA (Min to Max)
60 to 210
Air Circulation (Indoor – High Fan) Cooling
l/sec
500
Air Circulation (Indoor – High Fan) Heating
l/sec
500
Indoor Unit Dimensions
mm (Height x Width x Depth)
400 x 1050 x 500
Indoor Unit Weight
kg
38.00
Outdoor Unit Dimensions
mm (Height x Width x Depth)
716 x 820 x 315
Outdoor Unit Weight
kg
42.00
Piping Connects
mm Ø (Liquid / Gas)
6.35 / 12.7
Pipe Length
m (Max (Precharged))
30 (20)
Max Height Difference
m
25
Operation Range Cooling
°CDB (Min to Max)
-10 to 50
Operation Range Heating
°CDB (Min to Max)
-15 to 24
Refrigerant Type R32
Refrigerant Amount
g
1,250

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383