Fujitsu SET-ARTH60KHTA 15.5kW High Static Ducted System 1 Phase | Includes UTY-RNRT Controller


Price:
Sale price$5,150 Regular price$5,900

PLEASE NOTE:
Installation is only available in Sydney, Melbourne, and Brisbane.

Talk to us via our live chat or contact us page for a personalised quote.

Request a Personalised Quote

Direct Door to Door Delivery Available or Pick up option is available at multiple locations. Simply input your address at the checkout page, and the nearest pick-up depot will be displayed as one of your options.

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Description

Description

15.5kW Cooling
18.0kW Heating

Fujitsu SET-ARTH60KHTA 15.5kW High Static Ducted AC System | 1 Phase
Includes Indoor ARTH60KHTA | Outdoor AOTH60KBTA
Wired Remote Controller : UTY-RNRT – Backlit Touch Panel Wall Controller

Specification

Indoor unit ARTH60KHTA
Outdoor unit AOTH60KBTA
Operation Type Reverse Cycle
Power Source
V/Ph/Hz
230 / 1 / 50
Cooling Capacity
kW (Rated (Min – Max))
15.50 (5 – 16.5)
Heating Capacity
kW (Rated (Min – Max))
18.00 (5.1 – 19)
Input Power Cooling
kW (Rated (Max))
4.94 (6.02)
Input Power Heating
kW (Rated (Max))
4.89 (6.74)
EER Cooling
kW/kW
3.14
COP Heating
kW/kW
3.14
Star Rating Cooling
(0-10) (Hot / Average / Cold)
2.5 / 2.5 / 2.5
Star Rating Heating
(0-10) (Hot / Average / Cold)
2.5 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.378 / 4.193 / 4.416
Heating Seasonal Performance Factor Residential
kW (Hot / Average / Cold)
4.487 / 3.885 / 3.31
Total Cooling Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
4.673 / 4.821 / 5.181
Heating Seasonal Performance Factor Commercial
kW (Hot / Average / Cold)
4.491 / 4.135 / 3.523
Running Current
amps (Cooling / Heating)
21.7 / 21.4
Moisture Removal
l/hr
2.8
Indoor Sound Pressure Cooling
dBA (High / Quiet)
45 / 36
Indoor Sound Pressure Heating
dBA (High / Quiet)
45 / 36
Outdoor Sound Pressure
dBA (Cooling / Heating)
53 / 55
Outdoor Sound Power
dBA
71
Static Pressure Range
PA (Min to Max)
60 to 260
Air Circulation (Indoor – High Fan) Cooling
l/sec
986
Air Circulation (Indoor – High Fan) Heating
l/sec
986
Indoor Unit Dimensions
mm (Height x Width x Depth)
425 x 1250 x 490
Indoor Unit Weight
kg
53.00
Outdoor Unit Dimensions
mm (Height x Width x Depth)
1418 x 970 x 370
Outdoor Unit Weight
kg
95.00
Piping Connects
mm Ø (Liquid / Gas)
9.52 / 15.88
Pipe Length
m (Max (Precharged))
50 (30)
Max Height Difference
m
30
Operation Range Cooling
°CDB (Min to Max)
-10 to 50
Operation Range Heating
°CDB (Min to Max)
-15 to 24
Refrigerant Type R32
Refrigerant Amount
g
2,550

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383