Description

Ultra Compact Compact form factor - measuring at 200mm (H) and 620mm (D), makes it suitable for a variety of applications. Whisper-Quiet Noise levels are truly discrete and whisper quiet at 35dBA (25 Class Model). Auto-Fan-Speed An optimal fan speed is automatically selected to suit the set temperature for a more efficient operation. Flexible Return Air Option of a rear or bottom suction return allows for greater installation flexibility. Night Set Mode Temperatures are gently adjusted to prevent excessive cooling/heating for a more pleasant night's sleep. Standby Power Function Automatically reduces energy consumption when the system is not in use.


Shop with Confidence

    • Brand new Australian Stock
    • No Factory Seconds
    • Full Australian Manufacturer's Warranty
    • Authorized Genuine Dealer
    • Secure Online Payments

Specifications

INDOOR UNIT FDYBA71AV1
OUTDOOR UNIT RZAC71G2V1
Rated Capacity Cool (kW) 7.10
Heat (kW) 8.00
Capacity Range Cool (kW) 1.7-7.6
Heat (kW) 1.4-8.6
Power Input (Rated) Cool (kW) 2.12
Heat (kW) 2.20
E.E.R/C.O.P C/H 3.36/3.64
TCSPF (Residential) Hot/Average/Cold 4.62/4.29/4.46
HSPF (Residential) Hot/Average/Cold 6.09/4.13/3.28
Airflow Rate (Rated) l/s 325
Indoor Sound Level (H) @ 1.5m Discharge (dBA) 47.7
Suction (dBA) 46.2
Casing Breakout (dBA) 35.6
Piping Length m 30
Indoor Fan Speeds 5 Steps, Quiet and Automatic
Dimensions (HxWxD) Indoor (mm) 200x1100x450
Outdoor (mm) 695x930x350
Weight Indoor (kg) 24
Outdoor (kg) 128
Power Supply V/Hz 1 Phase 220-240V, 50Hz
Compressor Type Hermetically Sealed Swing Type
Refrigerant R32
Pipe Sizes Liquid (mm) 6.4 (Flared)
Gas (mm) 12.7 (Flared)
Drain (mm) ID 20 / OD 26
Supply Air Opening mm (HxW, Flange) 153×1060
Return Air Opening mm (HxW, Flange) 163×975
Outdoor Operating Range Cool (°CDB) -10 to 50
Heat (°CWB) -15 to 18
EPA Sound Power Level dBA 67
Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 53/55


Includes:
Indoor Unit : FDYBA71AV1
Outdoor Unit : RZAC71G2V1 (Old System Number: RZAC71GV1)
Controller : BRC4C65

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383

Customer Support

sales@wholesaleaircon.com.au

Send a message

Live chat / Text

You may also like

Recently viewed