Description

Compact & Sophisticated Design

  • Flaps neatly close When not in use.
  • Fresh white colour.

Comfort

  • Auto swing (up and down) and wide-angle louvers (left and right by hand) facilitate even room temperature.
  • Wide-angle louvers (by hand) Soft material louver bends airflow over a wider area
  • An air discharge modes ensure comfortable air distribution across the entire room
  • Comfort even on the far side of the room

To carry air to the far side of long rooms, extra-high airflow adds 10% more fan speed the “high” setting. Air discharge strength is selected from the remote controller by the field
setting.

  • Switchable fan speed: 3 steps and Auto – “Auto” is applicable when a wired remote controller is used.
  • Programme “Dry” – Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.

Design and Installation Flexibility

  • 6-direction refrigerant piping offers greater installation flexibility
  • Maintenance possible from the front of the unit
  • Drain pump kit is available as option – Drain pump kit can be installed on either left and right side of the indoor unit.

Interlock control

As an energy saving feature, the air conditioner can be interlocked with the key card system. Using a 3rd-party building management system,
air conditioning and lighting can be interlocked.

DIII-NET communication standard

Connection to a centralised control system is available without need for an optional adaptor.

Easy Cleaning

  • Removable and washable grille
  • Flat panel, easy to wipe dust off
  • Non-flocking flaps

Condensation does not easily form and dirt does not cling to non-flocking flaps. It is easy to clean

Shop with Confidence

Brand new Australian Stock
No Factory Seconds
Full Australian Manufacturer's Warranty
Authorised Genuine Dealer
Secure Online Payments

Specification

 

 

Model Name

Indoor unit FAA71BVMA
Outdoor unit RZAV71C2Y1
Power supply 3 Phase, 380-415V, 50Hz
Cooling capacity1,3 Rated (Min. – Max.)  

 

kW

7.1

 

(3.2-8.0)

Heating capacity2,3 Rated (Min. – Max.)  

 

kW

8.0

 

(3.5-9.0)

Power consumption Cooling1 kW 2.22
Heating2 kW 2.37
EER Cooling kW/kW 3.20
COP Heating kW/kW 3.38
AEER Cooling 3.13
ACOP Heating 3.31
TCSPF (Cooling) Commercial / Residential Hot 4.85 / 4.46
Average 4.88 / 3.92
Cold 5.19 / 4.00
HSPF (Heating) Commercial / Residential Hot 4.47 / 4.46
Average 4.16 / 3.94
Cold 3.79 / 3.52
Indoor unit Colour Fresh White
Airflow rate (H / M / L) /s 300 / 267 / 233
m3/min 18.0 / 16.0 / 14.0
Sound pressure level4 (H / M / L) dB(A) 45.0 / 42.0 / 40.0
Dimensions (HXWXD) mm 290X1,050X238
Machine weight kg 13
Certified operation range Cooling °CWB 14 to 25
Heating °CDB 15 to 27
Outdoor Colour Ivory White
unit Compressor Type Hermetically sealed swing type
Motor output kW 2.40
Refrigerant charge (R-32)  

 

kg

2.60

 

(Charged for 30 m)

Sound pressure level4 Cooling / Heating dB(A) 48 / 50
Night quiet mode dB(A) 44
Sound power level dB(A) 67
Dimensions (HXWXD) mm 990X940X320
Machine weight kg 69
Certified operation range Cooling °CDB -5 to 50
Heating °CWB -15 to 15.5
Piping connections Liquid (Flare) mm o/ 9.5
Gas (Flare) mm o/ 15.9
Drain Indoor unit mm VP13 (I.D. o/ 13XO.D. o/ 18)
Outdoor unit mm o/ 26.0 (Hole)
Max. interunit piping length m 75 (Equivalent length 90)
Max. installation height difference m 30
Heat insulation Both liquid and gas piping

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383