Description
Compact & Sophisticated Design
- Flaps neatly close When not in use.
- Fresh white colour.
Comfort
- Auto swing (up and down) and wide-angle louvers (left and right by hand) facilitate even room temperature.
- Wide-angle louvers (by hand) Soft material louver bends airflow over a wider area
- An air discharge modes ensure comfortable air distribution across the entire room
- Comfort even on the far side of the room
To carry air to the far side of long rooms, extra-high airflow adds 10% more fan speed the “high” setting. Air discharge strength is selected from the remote controller by the field
setting.
- Switchable fan speed: 3 steps and Auto – “Auto” is applicable when a wired remote controller is used.
- Programme “Dry” – Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.
Design and Installation Flexibility
- 6-direction refrigerant piping offers greater installation flexibility
- Maintenance possible from the front of the unit
- Drain pump kit is available as option – Drain pump kit can be installed on either left and right side of the indoor unit.
Interlock control
As an energy saving feature, the air conditioner can be interlocked with the key card system. Using a 3rd-party building management system,
air conditioning and lighting can be interlocked.
DIII-NET communication standard
Connection to a centralised control system is available without need for an optional adaptor.
Easy Cleaning
- Removable and washable grille
- Flat panel, easy to wipe dust off
- Non-flocking flaps
Condensation does not easily form and dirt does not cling to non-flocking flaps. It is easy to clean
Shop with Confidence
Brand new Australian Stock
No Factory Seconds
Full Australian Manufacturer's Warranty
Authorised Genuine Dealer
Secure Online Payments
Specification
71 | ||||
Model Name |
Indoor unit | FTXC71AV1A | ||
Outdoor unit | RXC71AV1A | |||
Power supply | 1 Phase, 220-240V, 50Hz | |||
Cooling capacity1,3 Rated (Min. – Max.) |
kW |
7.1
(3.2-8.0) |
||
Heating capacity2,3 Rated (Min. – Max.) |
kW |
8.0
(3.5-9.0) |
||
Power consumption | Cooling1 | kW | 2.22 | |
Heating2 | kW | 2.37 | ||
EER | Cooling | kW/kW | 3.20 | |
COP | Heating | kW/kW | 3.38 | |
AEER | Cooling | 3.13 | ||
ACOP | Heating | 3.31 | ||
TCSPF (Cooling) Commercial / Residential | Hot | 4.86 / 4.46 | ||
Average | 4.89 / 3.94 | |||
Cold | 5.20 / 4.02 | |||
HSPF (Heating) Commercial / Residential | Hot | 4.47 / 4.46 | ||
Average | 4.16 / 3.94 | |||
Cold | 3.79 / 3.52 | |||
Indoor unit | Colour | Fresh white | ||
Airflow rate (H / M / L) | /s | 300 / 267 / 233 | ||
m3/min | 18.0 / 16.0 / 14.0 | |||
Sound pressure level4 (H / M / L) | dB(A) | 45.0 / 42.0 / 40.0 | ||
Sound power level (H / M / L) | dB(A) | 61 / 58 / 56 | ||
Dimensions (HXWXD) | mm | 290X1,050X238 | ||
Machine weight | kg | 13 | ||
Certified operation range | Cooling | °CWB | 14 to 25 | |
Heating | °CDB | 15 to 27 | ||
Outdoor | Colour | Ivory White | ||
unit | Compressor | Type | Hermetically sealed swing type | |
Motor output | kW | 2.4 | ||
Refrigerant charge (R-32) |
kg |
2.60
(Charged for 30 m) |
||
Sound pressure level 4 | Cooling / Heating | dB(A) | 48 / 50 | |
Night quiet mode | dB(A) | 44 | ||
Sound power level | dB(A) | 67 | ||
Dimensions (HXWXD) | mm | 990X940X320 | ||
Machine weight | kg | 69 | ||
Certified operation range | Cooling | °CDB | -5 to 50 | |
Heating | °CWB | -15 to 15.5 | ||
Piping connections | Liquid (Flare) | mm | o/ 9.5 | |
Gas (Flare) | mm | o/ 15.9 | ||
Drain | Indoor unit | mm | VP13 (I.D.o/ 13XO.D. o/ 18) | |
Outdoor unit | mm | o/ 26.0 (Hole) | ||
Max. interunit piping length | m | 75 (Equivalent length 90) | ||
Max. installation height difference | m | 30 | ||
Heat insulation | Both liquid and gas piping |
Buyers Guide
Product Availability
We do not list stock levels on our website due to the wide variety of products we carry. Some items are directly sourced from suppliers, while others are stored in our partner local warehouses across Sydney, Brisbane, and Melbourne.
Once you has been confirmed, it undergoes a thorough processing stage to ensure all details are accurate. During this time, we check stock availability within 24 to 72 business hours.
If any supply issues arise, a member of our customer service team will promptly reach out to you via phone, email, or text to confirm your order and provide an update on the stock status.
FAQ, Warranty & Returns
All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.
Important Information to Maintain Your Warranty!
- Keep a copy of your invoice
- Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
- Ensure operation is as per manufacturer’s instructions.
- Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
- Replace exhausted batteries in remote control.
- If your system fails, contact the manufacturer without delay.
We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.
Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).
We are always looking to expand our product range and are constantly releasing the latest products and models.
The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide
2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS
- Bedrooms
- Studys
- Small lounges
- Small kitchens
- Small offices
3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS
- Bedrooms
- Bedrooms with ensuites
- Studys
- Small lounges
- Mid-sized kitchens
- Small rooms with high ceilings
- Offices
5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS
- Large bedrooms
- Bedrooms with ensuites
- Studys
- Mid-size lounges
- Large kitchens
- Mid-sized rooms with high ceilings
- Offices
7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS
- Large lounges
- Large open plan areas
- Small shops
- Offices
For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.
If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383
FAQ, Warranty & Returns
If we still haven't answered your question, you can contact us below and we will get back to you as soon as possible.