DAIKIN XL 8.0kW FTXV80W Reverse Cycle Split System Air Conditioner

New

Price:
Sale price$2,664

PLEASE NOTE:
Installation is only available in Sydney, Melbourne, and Brisbane.

Talk to us via our live chat or contact us page for a personalised quote.

Request a Personalised Quote

Direct Door to Door Delivery Available or Pick up option is available at multiple locations. Simply input your address at the checkout page, and the nearest pick-up depot will be displayed as one of your options.

13 May. Estimated arrival
10 May. Order placed
11-12 May. Order dispatches
13 May. Delivered!

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Description


Experience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer's Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock - never a factory second in sight!

Description

8.0kW Cooling | 9.0kW Heating
DAIKIN XL FTXV80W 8.0kW Reverse Cycle Inverter Split System Air Conditioner

Includes:
Indoor unit  FTXV80WVMA
Outdoor unit RXV80WVMA
Wireless Remote

Powerful airflow delivery, large capacity model designed for large open living.

Shop with Confidence

Brand new Australian Stock
No Factory Seconds
Full Australian Manufacturer's Warranty
Authorised Genuine Dealer
Secure Online Payments

Specifications

Model Indoor Unit FTXV80WVMA
Outdoor Unit RXV80WVMA
Cooling Heating
Capacity (Rated)
(Min. — Max.) / Half / Low Temperature
kW 8.000 (2.000 – 10.500) / 4.000 / — 9.000 (1.900 – 11.600) / 4.500 / 8.500
Btu/h 27,300 (6,800 – 35,800) / 13,600 /— 30,700 (6,500 – 39,600) / 15,400 / 29,000
kcal/h 6,880 (1,720 – 9,030) / 3,440 / — 7,740 (1,630 – 9,980) / 3,870 / 7,310
Moisture Removal L/h 5.2
Running Current (Rated) A 10.3 – 9.8 – 9.4 / 10.3 – 9.8 13.0 – 12.5- 11.9 / 13.0 – 12.5
Power Consumption (Rated) (Min. — Max.)
/ Half / Low Temperature
w 2,170 (400 – 3,670) / 780 / — 2,750 (410 – 4,130) / 960 / 3,180
Power Factor (Rated) % 95.8 – 96.3 – 96.2 / 95.8 – 96.3 96.2 – 95.7 – 96.3 / 96.2 – 95.7
COP (Rated) W/W 3.69 3.27
AEER / ACOP 3.66 3.254
Liquid (mm) 6.4 6.4
Piping Connections Gas (mm) 15.9 15.9
Drain (mm) 16 16
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30 30
Max. Interunit Height Difference m 20 20
Chargeless m 10 10
Amount of Additional Charge of Refrigerant g/m 20 20
Indoor Unit FTXV80WVMA
Front Panel Colour (Munsell No.) White (N9.5)
Airflow Rate H (m3/min (cfm)) 24.6 (869) 24.2 (855)
M  (m3/min (cfm)) 20.5 (724) 18.3 (646)
L (m3/min (cfm)) 16.5 (583) 14.0 (494)
SL (m3/min (cfm)) 14.4 (508) 12.4 (438)
Type Cross Flow Fan
Fan Motor Output (w) 103
Speed (Steps) 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof
Running Current (Rated) A 0.75 – 0.72 -0.69/0.75- 0.72 0.72 – 0.69- 0.66/0.72 – 0.69
Power Consumption (Rated) w 88 85
Power Factor (Rated) % 53.3 – 53.1 -53.1 / 53.3- 53.1 53.7 – 53.6- 53.7 / 53.7 – 53.6
Temperature Control Microcomputer Control
Dimensions (H x W x D) mm 329 x 1,240 x 278
Packaged Dimensions (H x W x D) mm 405 x 1,349 x 421
Weight (Mass) kg 19
Gross Weight (Gross Mass) kg 27
Sound Pressure Level / H/ M / L / SL dB(A) 51 / 46/40/37 51 / 45/38/35
Sound Power Level dB 67 67
Outdoor Unit RXV80WVMA
Casing Colour Ivory White
Heat Exchanger Fin / Spec. Tube Waffle Fin / 7 Hi-XD Tube
Compressor Type Hermetically Sealed Swing Type
Model 2YC71BXD
Motor Output (w) 2,400
Refrigerant Oil Type FW68DA
Charge (L) 0.9000
Refrigerant Type R-32
Charge (kg) 2.13
Airflow Rate H (m3/min (cfm)) 70.5 (2,489) 65.9 (2,327)
SL (m3/min (cfm)) 60.4 (2,133) 51.3 (1,81 1)
Type Propeller
Fan Motor Output (w) 117
Running Current (Rated) A 9.60 – 9.10 – 8.70/9.60 – 9.10 12.30 – 1 1.80 – 1 1.20/12.30 – 11.80
Power Consumption (Rated) w 2,082 2,665
Power Factor (Rated) % 98.6 – 99.5 – 99.7 /98.6 – 99.5 98.5 – 98.2 – 99.1 /98.5 – 98.2
Starting Current A 13
Dimensions (H x W x D) mm 990 x 940 x 320
Packaged Dimensions (H x W x D) mm 1,114 x 1,003 x 396
Weight (Mass) kg 77
Gross Weight (Gross Mass) kg 87
Sound Pressure Level H/ SL – dB(A) 54/51 55 / 51
Sound Power Level H (dB) 66 67
Drawing No. 3D142726A

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383

Customer support

Send a message

Live chat or sales@wholesaleaircon.com.au

You may also like

Recently viewed