Description
Description
18.0kW Cooling | 20.0kW Heating
FUJITSU SET-ARTG65LHTA 18.0kW Inverter Ducted Air Conditioner System 3 Phase
Includes Indoor ARTG65LHTA | Outdoor AOTG65LRLA
Lightweight | Compact Indoor Unit | Separable
Wired Back lit Controller – UTY-RVNYN
Specification
Operation Type
|
Reverse Cycle |
---|---|
Power SourceV/Ph/Hz
|
415 / 3 / 50 |
Cooling CapacitykW (Rated (Min – Max))
|
18.00 (8.4 – 20.0) |
Heating CapacitykW (Rated (Min – Max))
|
20.00 (7.2 – 22.0) |
EER CoolingkW/kW
|
3.09 |
COP HeatingkW/kW
|
3.77 |
Star Rating Cooling(0-10) (Hot / Average / Cold)
|
2.5 / 2.0 / 2.0 |
Star Rating Heating(0-10) (Hot / Average / Cold)
|
3.0 / 2.5 / 2.0 |
Total Cooling Seasonal Performance Factor ResidentialkW (Hot / Average / Cold)
|
4.121 / 3.816 / 3.936 |
Heating Seasonal Performance Factor ResidentialkW (Hot / Average / Cold)
|
4.609 / 4.167 / 3.819 |
Total Cooling Seasonal Performance Factor CommercialkW (Hot / Average / Cold)
|
4.413 / 4.473 / 4.764 |
Heating Seasonal Performance Factor CommercialkW (Hot / Average / Cold)
|
4.614 / 4.348 / 4.036 |
Moisture Removall/hr
|
4.5 |
Indoor Sound Pressure CoolingdBA (High / Quiet)
|
45 / 36 |
Indoor Sound Pressure HeatingdBA (High / Quiet)
|
45 / 36 |
Outdoor Sound PressuredBA (Cooling / Heating)
|
51 / 53 |
Outdoor Sound PowerdBA
|
70 |
Static Pressure RangePA (Min to Max)
|
60 to 200 |
Air Circulation (Indoor – High Fan) Coolingl/sec
|
1139 |
Air Circulation (Indoor – High Fan) Heatingl/sec
|
1139 |
Indoor Unit Dimensionsmm (Height x Width x Depth)
|
360 x 1400 x 850 |
Indoor Unit Weightkg
|
69.00 |
Outdoor Unit Dimensionsmm (Height x Width x Depth)
|
1428 x 1080 x 480 |
Outdoor Unit Weightkg
|
163.00 |
Piping Connectsmm Ø (Liquid / Gas)
|
12.7 / 25.4 |
Pipe Lengthm (Max (Precharged))
|
75 (30) |
Max Height Differencem
|
30 |
Operation Range Cooling°CDB (Min to Max)
|
-15 to 46 |
Operation Range Heating°CDB (Min to Max)
|
-15 to 24 |
Refrigerant Type
|
R410A |
Refrigerant Amountg
|
5,600 |
Buyers Guide
Product Availability
We do not list stock levels on our website due to the wide variety of products we carry. Some items are directly sourced from suppliers, while others are stored in our partner local warehouses across Sydney, Brisbane, and Melbourne.
Once you has been confirmed, it undergoes a thorough processing stage to ensure all details are accurate. During this time, we check stock availability within 24 to 72 business hours.
If any supply issues arise, a member of our customer service team will promptly reach out to you via phone, email, or text to confirm your order and provide an update on the stock status.
FAQ, Warranty & Returns
All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.
Important Information to Maintain Your Warranty!
- Keep a copy of your invoice
- Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
- Ensure operation is as per manufacturer’s instructions.
- Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
- Replace exhausted batteries in remote control.
- If your system fails, contact the manufacturer without delay.
We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.
Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).
We are always looking to expand our product range and are constantly releasing the latest products and models.
The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide
2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS
- Bedrooms
- Studys
- Small lounges
- Small kitchens
- Small offices
3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS
- Bedrooms
- Bedrooms with ensuites
- Studys
- Small lounges
- Mid-sized kitchens
- Small rooms with high ceilings
- Offices
5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS
- Large bedrooms
- Bedrooms with ensuites
- Studys
- Mid-size lounges
- Large kitchens
- Mid-sized rooms with high ceilings
- Offices
7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS
- Large lounges
- Large open plan areas
- Small shops
- Offices
For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.
If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383
FAQ, Warranty & Returns
If we still haven't answered your question, you can contact us below and we will get back to you as soon as possible.