FUJITSU SET-ARTG18LLTA 5.2kW Inverter Bulkhead Ducted System 1 Phase


Price:
Sale price$2,290

PLEASE NOTE:
Installation is only available in Sydney, Melbourne, and Brisbane.

Talk to us via our live chat or contact us page for a personalised quote.

Request a Personalised Quote

Direct Door to Door Delivery Available or Pick up option is available at multiple locations. Simply input your address at the checkout page, and the nearest pick-up depot will be displayed as one of your options.

13 May. Estimated arrival
10 May. Order placed
11-12 May. Order dispatches
13 May. Delivered!

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Description

Experience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer's Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock - never a factory second in sight!

Shop with Confidence

Brand new Australian Stock
No Factory Seconds
Full Australian Manufacturer's Warranty
Secure Online Payments

Specification

Model No. Indoor ARTG18LLTA
Model No. Outdoor AOTG18LACC
Reverse Cycle System Yes
Capacity Class _
Cooling Capacity (Watts) 5,200
Cooling Capacity (BTU/h) 17,700
Range (Watts) 900 5,900
Range (BTU/h) 3,100 20,100
Heating Capacity (Watts) 6,000
Heating Capacity (BTU/h) 20,500
Range (Watts) 900 7,500
Range (BTU/h) 3,100 25,600
Power Supply (Volts) 240
Phase-Frequency (Ph Hz) 1 50
Power Supply Attachment Outdoor
Plug Size (If Applicable) N/A
Running Current, Cooling (Amps) 6.1
Running Current, Range (Amps) Max 9.6
Input, Cooling (Watts) 1,450
Input, Range (Watts) Max 1,610
Running Current, Heating (Amps) 6.6
Running Current, Range (Amps) Max 13.1
Input, Heating (Watts) 1,560
Input, Range (Watts) Max 2,310
Input (Watts)
Moisture Removal (l/hr) 2
E.E.R. Cooling 3.59
C.O.P. Heating 3.85
Star Rating Cooling _
Star Rating Heating _
Fan Speed 4
Air Circulation, High (l/s) 261
Compressor Type DC Twin Rotary
Dimensions Inside Unit (HxWxD mm) 198 x 900 x 620
Weight Inside Unit (kg) 23
Dimensions Outside Unit (HxWxD mm) 620 x 790 x290
Weight Outside Unit (kg) 41
I.U. Sound Pressure Level (dBA@1mtr) 32
O.U. Sound Pressure Level (dBA@1mtr) 55
O.U. Sound Power Level (dBA) 71
Refrigerant Type R410A
Connection Pipe Sizes, Gas (mm) 12.7
Connection Pipe Sizes, Liquid (mm) 6.35
Pre Charged Length (Metre) 15
Minimum Pipe Length (Metre) 3
Maximum Pipe Length (Metre) 30
Maximum Pipe Height (Metre) 20
Pipe Connection Methods Flare
Outdoor operating Temp, Cooling_ -10 to 46
Outdoor operating Temp, Heating_ -15 to 24

Features

Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.

Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.

ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.

Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.

Connectable Distributing Duct
Conditioned air can be distributed to adjacent areas by means of a distribution duct.

Weekly Timer
Different on-off times can be set for up to 7 days.

Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.

Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.

ALL DC
With All DC, electricity loss is decreased and power consumption reduced.

Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.

Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only

Description

5.2 kW Cooling
6.0 kW Heating
Blue Fin Heat Exchanger

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383