MITSUBISHI ELECTRIC PEAD-M140JAADR1.TH / PUZ-ZM140YKA-A.TH 14kW Ducted Air Conditioner System 3 Phase


Price:
Sale price$5,934

PLEASE NOTE:
Installation is only available in Sydney, Melbourne, and Brisbane.

Talk to us via our live chat or contact us page for a personalised quote.

Request a Personalised Quote

Direct Door to Door Delivery Available or Pick up option is available at multiple locations. Simply input your address at the checkout page, and the nearest pick-up depot will be displayed as one of your options.

Payment & Security

American Express Apple Pay Google Pay Mastercard PayPal Shop Pay Union Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Description

Experience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer's Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock - never a factory second in sight!

Specifications

Ceiling-Concealed (PEAD-ZM Series)
Indoor Unit PEAD-M140JAA(D)
Outdoor Unit Ê Refrigerant PUZ-ZM 140YKA
R32
Power Supply V:230V, Single-phase, 50Hz Y:400V, Three-phase, 50Hz
Capacity (kW) 6.2-14.0-15.3
[Min-Rated-Max]
Total Input [Rated] (kW) 4.37
AEER/EER 3.09 / 3.20
Cooling AEER [Part-load %] *1 4.09
7.40
Running Current [Rated] A
Sound In (Lo-Mid-Hi) Pressure Ê dB(A) 40-44-49
Level Out (PWL) 50 (70)
Air Volume (In) Lo-Mid-Hi L/S 533-650-767
Capacity Ê (kW) Ê 5.7-16.0-18.0
[Min-Rated-Max]
Total Input [Rated] (kW) 4.18
Ê Heating ACOP/COP Running Current [Rated] (mm) 3.69 / 3.82
7.10
Sound In (Lo-Mid-Hi) dB(A) 40-44-49
Level Out (PWL) Air Volume (In) Lo-Mid-Hi dB(A) 52 (71)
533-650-767
Max. Running Current A 14.10
Ê Ê Indoor Unit Input [Rated] kW (0.39) / 0.37
Dimensions [HxWxD] mm 250 x 1600 x 732
Weight kg 44
Static Pressure Pa 35 / 50 / 70 / 100 / 125
Ê Outdoor Unit Dimensions [HxWxD] mm 1338 x 1050 x 330 (+40)
Weight kg 112
Breaker Size A 16
Ext. Piping Diameter [Gas/Liquid] mm 15.88 / 9.52
Max. Length/Height m 75 / 30
Guaranteed Cooling*2 C -5(-15) ~ 52
Operating Range [Outdoor] Supply Air Duct Heating C -20 ~ 21
mm 1560 x 178
Precharge Refrigerant kg 4 (30m)
Ê Additional Refrigerant per M(g) Ê 40

Shop with Confidence


  • Brand new Australian Stock

  • No Factory Seconds

  • Full Australian Manufacturer's Warranty

  • Secure Online Payments

Description

14.0 kW Cooling
16.0 kW Heating
Power Inverter | ZM Series

Buyers Guide

FAQ, Warranty & Returns

All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.

Important Information to Maintain Your Warranty!

  • Keep a copy of your invoice
  • Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
  • Ensure operation is as per manufacturer’s instructions.
  • Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
  • Replace exhausted batteries in remote control.
  • If your system fails, contact the manufacturer without delay.

We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.

Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).

We are always looking to expand our product range and are constantly releasing the latest products and models.

The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide

2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS

  • Bedrooms
  • Studys
  • Small lounges
  • Small kitchens
  • Small offices

3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS

  • Bedrooms
  • Bedrooms with ensuites
  • Studys
  • Small lounges
  • Mid-sized kitchens
  • Small rooms with high ceilings
  • Offices

5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS

  • Large bedrooms
  • Bedrooms with ensuites
  • Studys
  • Mid-size lounges
  • Large kitchens
  • Mid-sized rooms with high ceilings
  • Offices

7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS

  • Large lounges
  • Large open plan areas
  • Small shops
  • Offices

For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.

If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383

Customer Support

sales@wholesaleaircon.com.au

Send a message

Live chat / Text

You may also like

Recently viewed