Description
Experience the ultimate in cooling comfort with our premium selection of wholesale air conditioners. All units come with a full Australian Manufacturer's Warranty for your peace of mind. Enjoy brand new, top-of-the-line air conditioners sourced directly from Australian stock - never a factory second in sight!
Features
POWERFUL MODE
Pressing the Powerful button cools or heats the room quickly. It provides fast comfort, with full power and a strong airflow. This is perfect for use immediately after coming home, or when unexpected guests arrive.
SLEEP MODE
Delays off timer with temperature control for better sleep.
QUIET MODE
Enjoy the comfort of running your air conditioner at night for a relaxing sleep.
PERSONAL AIRFLOW CREATION
Vertical and horizontal airflow patterns can be combined as desired to achieve optimum comfort, with operation possible by remote even from a distance.
FAN MODE
Allows you to run the fan without any cooling or heating, thus giving just ventilation.
AUTO CHANGEOVER (INVERTER)
In Auto Mode, the unit will select if heating or cooling is required.
SOFT DRY OPERATION MODE
Starts with cooling to dehumidify, then provides continuous breeze at a low frequency to keep a room dry without much change to the temperature
HOT START CONTROL
On the start of the heating cycle and after the defrost cycle, the indoor fan will start up once the indoor heat exchanger is warm.
AIRFLOW DIRECTION CONTROL (UP & DOWN)
Vertical airflow patterns can be controlled with operation by remote, even from a distance. * Applicable to CS-RZ25XKRW, CS-RZ35XKRW, CS-RZ42XKRW & CS-RZ50XKRW
Shop with Confidence
- Brand new Australian Stock
- No Factory Seconds
- Full Australian Manufacturer's Warranty
- Authorized Genuine Dealer
- Secure Online Payments
Specifications
MODEL | (240V / 1 Phase / 50Hz) | CS-RZ25XKRW
[CU-RZ25XKR] |
||||
Cooling / Heating | (min-max) | kW | 2.50 [0.95-3.70] | |||
3.00 [0.90-4.40] | ||||||
Capacity | (min-max) | Btu/h | 8,530 [3,240-12,600] | |||
10,200 [3,070-15,000] | ||||||
Air Flow | Indoor | L/s | 188/200 | |||
Dehumid | L/h |
1.5 |
||||
Running Current | A | 2.50/2.80 | ||||
Electrical Data | Max Current | A | 6.4 | |||
Power Input (min-max) | kW | 0.57 (0.22-1.20) | ||||
0.64 (0.19-1.29) | ||||||
AEER / EER | W/W | 4.32/4.39 | ||||
ACOP / COP | W/W | 4.63/4.69 | ||||
Hot Climate | Cooling | 4.5 | ||||
Heating | 3.5 | |||||
Star Rating | Average Climate | Cooling | 4.0 | |||
Heating | 3.0 | |||||
Cold Climate | Cooling | 4.0 | ||||
Heating | 2.5 | |||||
TCSPF & HSPF Residential/ Commercial |
Hot Climate | TCSPF HSPF | 6.46/7.53
5.12/5.11 |
|||
Average Climate | TCSPF HSPF | 5.77/8.13
4.72/4.86 |
||||
Cold Climate | TCSPF HSPF | 5.94/9.70
4.13/4.37 |
||||
Noise Level | Indoor (H / L / Q-Lo) | 40/25/19 | ||||
Sound Pressure | 40/27/21 | |||||
Outdoor (H / Q-Lo) | ||||||
Level*2 dB(A) | 48/43
49/44 |
|||||
Indoor (H / L / Q-Lo) | 56/41/35 | |||||
Sound Power | 56/43/37 | |||||
Level dB(A) | ||||||
Outdoor (H / Q-Lo) | 63/58 | |||||
64/59 | ||||||
Net Weight | Indoor (Outdoor) | kg |
8(25) |
|||
Dimensions | Indoor (H x W x D) | mm | 290 x 779 x 209 | |||
Outdoor (H x W x D) | mm | 542 x 780 x 289 | ||||
Refrigerator Pipe Liquid Side mm/(inch) | ø 6.35 (1/4) | |||||
Diameter Gas Side mm/(inch) | ø 9.52 (3/8) | |||||
Pipe Extension Length Min ~ Max (m) |
3~20 |
|||||
Maximum Elevation Length m |
15 |
|||||
Pipe Length For Additional Gas m | 7.5 | |||||
Additional Gas Amount g/m | 10 | |||||
Operating Range (Outdoor) Cooling Degree °C
Heating |
-10 ~ +46
-15 ~ +24 |
Buyers Guide
Product Availability
We do not list stock levels on our website due to the wide variety of products we carry. Some items are directly sourced from suppliers, while others are stored in our partner local warehouses across Sydney, Brisbane, and Melbourne.
Once you has been confirmed, it undergoes a thorough processing stage to ensure all details are accurate. During this time, we check stock availability within 24 to 72 business hours.
If any supply issues arise, a member of our customer service team will promptly reach out to you via phone, email, or text to confirm your order and provide an update on the stock status.
FAQ, Warranty & Returns
All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.
Important Information to Maintain Your Warranty!
- Keep a copy of your invoice
- Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
- Ensure operation is as per manufacturer’s instructions.
- Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
- Replace exhausted batteries in remote control.
- If your system fails, contact the manufacturer without delay.
We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.
Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).
We are always looking to expand our product range and are constantly releasing the latest products and models.
The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide
2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS
- Bedrooms
- Studys
- Small lounges
- Small kitchens
- Small offices
3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS
- Bedrooms
- Bedrooms with ensuites
- Studys
- Small lounges
- Mid-sized kitchens
- Small rooms with high ceilings
- Offices
5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS
- Large bedrooms
- Bedrooms with ensuites
- Studys
- Mid-size lounges
- Large kitchens
- Mid-sized rooms with high ceilings
- Offices
7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS
- Large lounges
- Large open plan areas
- Small shops
- Offices
For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.
If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383
FAQ, Warranty & Returns
If we still haven't answered your question, you can contact us below and we will get back to you as soon as possible.