Technical Specifications SYSTEM | 120 | |||||
Nominal Capacity | kW | 12 | ||||
Power Supply (To Outdoor Unit) | V- Ph-Hz | 220~240 1 50 | ||||
Maximum Input Power | W | 5500 | ||||
Maximum Input Current | A | 26.0 | ||||
Recommended Circuit Breaker Size | 32 | |||||
Cooling | Rated Capacity | kW | 12.3 | |||
Capacity Range | 5.0 ~ 15.0 | |||||
Rated Input Power | W | 3690 | ||||
Stand By Power | 10 | |||||
Rated Input Current | A | 16.1 | ||||
AEER | W/W | 3.31 | ||||
Star Rating | _ | 2.0 | ||||
Heating | Rated Capacity | kW | 14.2 | |||
Capacity Range | 5.2 ~15.6 | |||||
Rated Input Power | W | 4030 | ||||
Stand By Power | 10 | |||||
Rated Input Current | A | 17.7 | ||||
ACOP | W/W | 3.49 | ||||
Star Rating | _ | 2.0 | ||||
Indoor Unit | CIN120R | |||||
Fascia Panel | Model No. | CINFAS | ||||
Rated Input | W | 250 | ||||
Air Flow (Hi / Med / Lo) | L/s | 639 / 556 / 500 | ||||
Sound Pressure Level @ 1.4m (Hi / Med / Lo) | dB(A) | 54 / 51 / 48 | ||||
Dimensions | Net Body (W x D x H) | mm | 840 x 840 x 287 | |||
Packing Body (W x D x H) | 900 x 900 x 300 | |||||
Net Fascia (W x D x H) | 950 x 950 x 55 | |||||
Packing Fascia (W x D x H) | 1035 x 1035 x 90 | |||||
Net / Gross Weight Body | kg | 28.7 / 32.8 | ||||
Net / Gross Weight Fascia | 5 / 8 | |||||
Condensate Drain Pipe Diameter | mm | OD_32 | ||||
Refrigerant Piping | Liquid / Gas Connections | _9.52/_19 | ||||
Standard Controller | Type | Wireless Remote | ||||
Operating Range | oC | Cooling: 17 ~ 32. Heating: 0 ~ 30 | ||||
Outdoor Unit | DONSR12Z72 | |||||
Power Supply | V- Ph-Hz | 220~240 1 50 | ||||
Maximum Input Power | W | 5500 | ||||
Maximum Input Current | A | 26.0 | ||||
Starting Current | 3.5 | |||||
Compressor | Type | Twin Rotary | ||||
Air Flow | L/s | 1944 | ||||
Sound Pressure Level @ 1m | dB(A) | 62 | ||||
Sound Power Level | 71 | |||||
Dimensions | Net (W _ D _ H) | mm | 952 x 415 x 1333 | |||
Packing (W x D x H) | 1095 x 495 x 1480 | |||||
Net / Gross Weight | kg | 100 / 114 | ||||
Refrigerant Piping | Type | R410A | ||||
Charged Volume | kg | 4.50 | ||||
Design Pressure | MPa | 4.2 / 1.5 | ||||
Pre-Charged Length | m | 15 | ||||
Charge Adjustment (Add or Remove) | g/m | 30 | ||||
Refrigerant Piping | Liquid / Gas Connections | mm | _9.52 / _19.0 | |||
Maximum Pipe Length | m | 65 | ||||
Maximum Vertical Separation | 30 | |||||
Features
360 Air FlowThe 360 Airflow Fascia ensures optimal air distribution and total comfort in every corner of the room.
Auto Restart Function
In the event of the power failure, the system will stop immediately. When the power returns, restart the systems and the unit will restart at the same settings.
Heating and Cooling
All year-round comfort, with full temperature control suited to your needs
Infrared Remote Control
Operation is via an attractive, ergonomically designed infrared remote control which incorporates a high visibility LCD display. An optional upgrade to the Rinnai wired programmable thermostat and Wi-Fi is also available.
Wi-Fi Control*
Set your favourite temperature from anywhere, with our intuitive Android or Apple App. Come home to ultimate comfort. *Wi-Fi optional
High Efficiency DC Inverter
More efficient that conventional electric heating, the DC inverter technology ensures a fast and controlled warm up and cool down while delivering effective energy savings.
Built-In Drain Pump
Cleverly engineered Built-in drain pump ensures condensed water is drained out reliably
Easy Service Access
The condensate drain pump is conveniently located in a separate compartment of the indoor unit providing maximum service access.
Description
12.3 kW Cooling14.2 kW Heating
360 Air Flow | High Efficiency
Buyers Guide
Product Availability
We do not list stock levels on our website due to the wide variety of products we carry. Some items are directly sourced from suppliers, while others are stored in our partner local warehouses across Sydney, Brisbane, and Melbourne.
Once you has been confirmed, it undergoes a thorough processing stage to ensure all details are accurate. During this time, we check stock availability within 24 to 72 business hours.
If any supply issues arise, a member of our customer service team will promptly reach out to you via phone, email, or text to confirm your order and provide an update on the stock status.
FAQ, Warranty & Returns
All systems sold by Wholesale Aircon have a 5 year manufacturers warranty. For more details refer to each Manufacturers warranty guidelines.
Important Information to Maintain Your Warranty!
- Keep a copy of your invoice
- Ensure your air conditioning installer is qualified and holds a current refrigeration handling license.
- Ensure operation is as per manufacturer’s instructions.
- Ensure the air inlet and outlet of the outdoor unit is kept clear of obstructions.
- Replace exhausted batteries in remote control.
- If your system fails, contact the manufacturer without delay.
We are unable to deliver to a PO Box as we need ID and a copy of the online receipt when delivery is made.
Wholesale Aircon can help guide you if a warranty issue arises. Firstly the client needs to contact the manufacturer. The number for each manufacturer will be on the warranty form which came with the system purchased. When placing a warranty claim you will need to provide proof of purchase (your tax invoice).
We are always looking to expand our product range and are constantly releasing the latest products and models.
The cooling and heating capacity of an air conditioner is measured in kilowatts (kW).
Airconditioner Sizing Guide
2.5 kW RANGE
SUITABLE FOR ROOMS APPROX 10 – 25 SQ METERS
- Bedrooms
- Studys
- Small lounges
- Small kitchens
- Small offices
3.5kW RANGE
SUITABLE FOR ROOMS APPROX 25 – 35 SQ METERS
- Bedrooms
- Bedrooms with ensuites
- Studys
- Small lounges
- Mid-sized kitchens
- Small rooms with high ceilings
- Offices
5 – 6kW RANGE
SUITABLE FOR ROOMS APPROX 35 – 60 SQ METERS
- Large bedrooms
- Bedrooms with ensuites
- Studys
- Mid-size lounges
- Large kitchens
- Mid-sized rooms with high ceilings
- Offices
7 – 8kW RANGE
SUITABLE FOR ROOMS APPROX 60 – 80 SQ METERS
- Large lounges
- Large open plan areas
- Small shops
- Offices
For more complex installations a heat load calculation should be performed. A heat load calculation comprises of many factors such as size of area, size of windows, roof type, building material, whether there is insulation, external shading or internal shading etc. Incorrect sizing will mean inadequate cooling/heating.
If you are unsure on sizing please email us, or go to Request a Quote or call 0473 575 383
FAQ, Warranty & Returns
If we still haven't answered your question, you can contact us below and we will get back to you as soon as possible.